Documentation
Log in
Log in
Build
Platform Introduction
Embedded Apps
What's NewOverviewDeveloper GuideSidebar API Quick Start
Design Guidelines
MessagingMeetingsDevicesSidebar
API Reference
BotsButtons and CardsIntegrationsBYODSService Apps G2GWidgetsLogin with WebexDeveloper SandboxBeta ProgramSupport PolicyFAQs
APIs
API Behavior ChangesXML API DeprecationAccess the APIREST API BasicsComplianceWebex APIs
Admin
OverviewAdmin APIsHybrid ServicesAuthentication
Guides
Hybrid ServicesWebhooksReal-time File DLP BasicsProvisioning APIsBackground ImagesAudit Events Error Reference
Reference
Admin Audit EventsAuthorizationsEventsGroupsHybrid ClustersHybrid ConnectorsLicensesMeeting QualitiesOrganizationsPartner Reports/TemplatesPeopleRecording ReportRecordingsReportsResource Group MembershipsResource GroupsRolesSecurity Audit EventsSession TypesSpace ClassificationsTracking CodesWorkspace LocationsWorkspace Metrics
Webex Calling Beta
Overview
Guides
Integrations and AuthorizationMetadata and Samples
Webex Calling
OverviewSDKs and ToolsWhat's New
Guides
Integrations and AuthorizationProvisioning APIsMetadata and SamplesBackground Images
Reference
Call ControlsCall RoutingCall Settings For MeCalling Service SettingsClient Call SettingsConference ControlsConverged RecordingsDevice Call SettingsDevicesEmergency Services SettingsFeatures: Announcement PlaylistFeatures: Announcement RepositoryFeatures: Auto AttendantFeatures: Call ParkFeatures: Call PickupFeatures: Call QueueFeatures: Customer Experience EssentialsFeatures: Hunt GroupFeatures: Operating ModesFeatures: Paging GroupFeatures: Single Number ReachLocation Call SettingsLocation Call Settings: Call HandlingLocation Call Settings: SchedulesLocation Call Settings: VoicemailLocationsNumbersPSTNPartner Reports/TemplatesPeopleRecording ReportReportsReports: Detailed Call HistorySend Activation EmailUser Call SettingsVirtual Line Call SettingsWorkspace Call SettingsWorkspaces
Webex for Broadworks
Overview
Guides
Integrations and AuthorizationDeveloper's Guide
Reference
BroadWorks Billing ReportsBroadWorks Subscribers
Webex for Wholesale
Overview
Guides
Developer's Guide
Reference
Wholesale Billing ReportsWholesale Provisioning
Contact Center
Overview
Devices
Overview
Guides
Devices
Reference
Device Call SettingsDevice ConfigurationsDevicesWorkspace LocationsWorkspace MetricsWorkspace PersonalizationWorkspacesxAPI
Directory Services
Reference
Domain ManagementIdentity Organization
Meetings
Overview
Guides
Integrations and AuthorizationWebhooksWebinar GuideMeeting Resource Guide
Reference
Meeting ChatsMeeting Closed CaptionsMeeting InviteesMeeting ParticipantsMeeting PollsMeeting PreferencesMeeting Q and AMeeting QualitiesMeetingsMeetings Summary ReportPeopleRecording ReportRecordingsSession TypesTracking CodesVideo MeshWebhooks
Messaging
Overview
Guides
BotsIntegrations and AuthorizationWebhooksButtons and Cards
Reference
Attachment ActionsEventsMembershipsMessagesPeopleRoom TabsRoomsTeam MembershipsTeamsWebhooks
SCIM 2
Overview
Reference
SCIM 2 BulkSCIM 2 GroupsSCIM 2 Users
FedRAMP
Overview
Guides
Create a BotCreate an IntegrationNotes on API Support
Workspace Integrations
OverviewTechnical DetailsControl Hub Features
Full API Reference
Admin Audit EventsAttachment ActionsAuthorizationsBroadWorks Billing ReportsBroadWorks SubscribersCall ControlsCall RoutingCall Settings For MeCalling Service SettingsClient Call SettingsConference ControlsConverged RecordingsDevice Call SettingsDevice ConfigurationsDevicesDomain ManagementEmergency Services SettingsEventsFeatures: Announcement PlaylistFeatures: Announcement RepositoryFeatures: Auto AttendantFeatures: Call ParkFeatures: Call PickupFeatures: Call QueueFeatures: Customer Experience EssentialsFeatures: Hunt GroupFeatures: Operating ModesFeatures: Paging GroupFeatures: Single Number ReachGroupsHybrid ClustersHybrid ConnectorsIdentity OrganizationIssuesLicensesLocation Call SettingsLocation Call Settings: Call HandlingLocation Call Settings: SchedulesLocation Call Settings: VoicemailLocationsMeeting ChatsMeeting Closed CaptionsMeeting InviteesMeeting ParticipantsMeeting PollsMeeting PreferencesMeeting Q and AMeeting QualitiesMeetingsMeetings Summary ReportMembershipsMessagesNumbersOrganizationsPSTNPartner Reports/TemplatesPeopleRecording ReportRecordingsReportsReports: Detailed Call HistoryResource Group MembershipsResource GroupsRolesRoom TabsRoomsSCIM 2 BulkSCIM 2 GroupsSCIM 2 UsersSecurity Audit EventsSend Activation EmailSession TypesSiteSpace ClassificationsTeam MembershipsTeamsTracking CodesUser Call SettingsVideo MeshVirtual Line Call SettingsWebhooksWholesale Billing ReportsWholesale ProvisioningWorkspace Call SettingsWorkspace LocationsWorkspace MetricsWorkspace PersonalizationWorkspacesxAPI
API Changelog
SDKs
Space Meetings Migration
Meetings
Introduction
Platform
Web
IntroductionQuickstart
Basics
AuthorizationJoin a MeetingMigration To Improved MeetingsPasswords & CaptchasUnified Space Meetings
Advanced Features
Advanced ControlsDialing In and OutStreams & EffectsVideo Resolution
Multistream
Multistream Comprehensive GuideMultistream Quickstart
Migrating SDK V2 to V3
iOSAndroidBrowserNode.js
Developer CommunityCertifications

Create a DECT Network

Create a multi-cell DECT network for a given location.

Creating a DECT network requires a full administrator auth token with a scope of spark-admin:telephony_config_write.

POST/telephony/config/locations/{locationId}/dectNetworks
URI Parameters
locationId
stringrequired

Create a DECT network in this location.

Query Parameters
orgId
string

Create a DECT network in this organization.

Body Parameters
name
stringrequired

Name of the DECT network. Min and max length supported for the DECT network name are 1 and 40 respectively.

displayName
string

Add a default name (11 characters max) to display for all handsets. If left blank, the default name will be an indexed number followed by the DECT network name.

model
enumrequired

Select a device model type depending on the number of base stations and handset lines needed in the DECT network. The corresponding device model display name sometimes called the product name, can also be used to specify the model.

DMS Cisco DBS110
string

Model name supporting 1 base station and 30 line ports.

Cisco DECT 110 Base
string

Alternate product/display name which also specifies the model DMS Cisco DBS110.

DMS Cisco DBS210
string

Supports 250 base stations and 1000 line ports.

Cisco DECT 210 Base
string

Alternate product/display name which also specifies the model DMS Cisco DBS210.

defaultAccessCodeEnabled
booleanrequired

If set to true, need to provide a default access code that will be shared for all users in this network to pair their lines to the next available handset. Otherwise, each user will get a unique 4-digit access code that will be auto-generated. Note: There is currently no public API to retrieve the auto generated access codes for handsets. Use Control Hub instead.

defaultAccessCode
stringrequired

If defaultAccessCodeEnabled is set to true, then provide a default access code that needs to be a 4-numeric digit. The access code should be unique to the DECT network for the location.

Response Properties
dectNetworkId
string

A unique identifier for the DECT network.

Response Codes

The list below describes the common success and error responses you should expect from the API:

CodeStatusDescription
200OKSuccessful request with body content.
201CreatedThe request has succeeded and has led to the creation of a resource.
202AcceptedThe request has been accepted for processing.
204No ContentSuccessful request without body content.
400Bad RequestThe request was invalid or cannot be otherwise served. An accompanying error message will explain further.
401UnauthorizedAuthentication credentials were missing or incorrect.
403ForbiddenThe request is understood, but it has been refused or access is not allowed.
404Not FoundThe URI requested is invalid or the resource requested, such as a user, does not exist. Also returned when the requested format is not supported by the requested method.
405Method Not AllowedThe request was made to a resource using an HTTP request method that is not supported.
409ConflictThe request could not be processed because it conflicts with some established rule of the system. For example, a person may not be added to a room more than once.
410GoneThe requested resource is no longer available.
415Unsupported Media TypeThe request was made to a resource without specifying a media type or used a media type that is not supported.
423LockedThe requested resource is temporarily unavailable. A Retry-After header may be present that specifies how many seconds you need to wait before attempting the request again.
428Precondition RequiredFile(s) cannot be scanned for malware and need to be force downloaded.
429Too Many RequestsToo many requests have been sent in a given amount of time and the request has been rate limited. A Retry-After header should be present that specifies how many seconds you need to wait before a successful request can be made.
500Internal Server ErrorSomething went wrong on the server. If the issue persists, feel free to contact the Webex Developer Support team.
502Bad GatewayThe server received an invalid response from an upstream server while processing the request. Try again later.
503Service UnavailableServer is overloaded with requests. Try again later.
504Gateway TimeoutAn upstream server failed to respond on time. If your query uses max parameter, please try to reduce it.
  • Try it
  • Example
POST
/telephony/config/locations//dectNetworks{?orgId}
Log in to try the API.
Header
Query Parameters
  • Create a DECT network in this organization.
Body
  • Name of the DECT network. Min and max length supported for the DECT network name are 1 and 40 respectively.
  • Add a default name (11 characters max) to display for all handsets. If left blank, the default name will be an indexed number followed by the DECT network name.
  • Select a device model type depending on the number of base stations and handset lines needed in the DECT network. The corresponding device model display name sometimes called the product name, can also be used to specify the model.
  • If set to true, need to provide a default access code that will be shared for all users in this network to pair their lines to the next available handset. Otherwise, each user will get a unique 4-digit access code that will be auto-generated. Note: There is currently no public API to retrieve the auto generated access codes for handsets. Use Control Hub instead.
  • If `defaultAccessCodeEnabled` is set to true, then provide a default access code that needs to be a 4-numeric digit. The access code should be unique to the DECT network for the location.
  • Request
  • Response
/telephony/config/locations/Y2lzY29zcGFyazovL3VzL0RFQ1RfREVWX05FVC81NmRiMjRkMy03YTdhLTQwYTItOWFjOS1iMjMzMjc3OTIxTrd/dectNetworks?orgId=Y2lzY29zcGFyazovL3VzL09SR0FOSVpBVElPTi85NmFiYzJhYS0zZGNjLTExZTUtYTE1Mi1mZTM0ODE5Y2RjOWE
    {
       "name": "test-dect",
       "displayName": "test-dect",
       "model" : "DMS Cisco DBS210",
       "defaultAccessCodeEnabled": true,
       "defaultAccessCode": "1551"
    }
201 / Created
{
  "dectNetworkId": "Y2lzY29zcGFyazovL3VzL0RFQ1RfREVWX05FVC81NmRiMjRkMy03YTdhLTQwYTItOWFjOS1iMjMzMjc3OTIxNzf"
}

Connect

Contact Sales

Resources

Open Source Bot Starter Kits

Download Webex

DevNet Learning Labs

Terms of Service

Privacy Policy

Cookie Policy

Trademarks

© 2025 Cisco and/or its affiliates. All rights reserved.